Windsor · Berkshire
Roof Lanterns in Windsor
We cover Windsor and the rest of Berkshire for roof lantern supply and fitting, from small skylights over landings to large lanterns for open-plan kitchens.
- SL4
- Guide from £1,095
Flat roof skylight in Windsor
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
The price of a roof lantern or skylight depends on the size and shape, glass specification, frame colour, opening vents or electric operation, and whether the upstand already exists or needs building. Access to the roof and lifting large units add labour. See the guide prices for typical ranges.
In England, Approved Document L sets a limiting U-value of 2.2 W/m²K for rooflights, calculated in the horizontal position, for both new and existing homes. A kerb or upstand built on site should achieve 0.35 W/m²K or better. Ask for the lantern's declared horizontal U-value, not a vertical figure.
Cutting a new opening for a roof lantern or skylight usually means trimming joists or rafters, so the roof can carry the load around the hole. Building regulations approval is generally needed for a new rooflight, covering structure, energy performance and, near a boundary, fire performance.
What you get
- Removal and disposal of an old lantern or skylight
- Survey of the roof, opening, upstand and drainage
- Written guarantee terms and manufacturer documentation
- Fixing, glazing and sealing onto the prepared upstand

Working in Windsor
- Postcodes covered
- SL4 and the surrounding area, including Slough, Egham and Staines
- Coast
- Windsor is well inland, around 67 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Windsor the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Windsor
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Approved Document L sets the minimum energy performance for replacement windows and doors in existing homes in England: a U-value of 1.4 W/m²K, or Window Energy Rating band B for windows; doors can instead meet a Door Set Energy Rating (band B, or band C for doors more than 60% glazed); rooflights need 2.2 W/m²K.
Options to choose between
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Roof Lanterns in Windsor: questions
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
Do you cover Windsor for roof lanterns?
Yes. We can quote for roof lanterns across Windsor and the surrounding Berkshire area, including postcode districts SL4, and nearby Slough, Egham and Staines. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Windsor
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.