Poole · Dorset
Roof Lanterns in Poole
Is the middle of your extension in Poole too dark? A roof lantern or skylight brings in light that wall windows cannot reach.
- BH15
- BH14
- BH17
- Guide from £1,095
Roof lantern replacement across Poole
Cutting a new opening for a roof lantern or skylight usually means trimming joists or rafters, so the roof can carry the load around the hole. Building regulations approval is generally needed for a new rooflight, covering structure, energy performance and, near a boundary, fire performance.
The Rooflight Association recommends laminated glass for the inner pane of glass rooflights, because laminated glass stays bonded together if it breaks instead of dropping fragments into the room below. Toughened inner panes are still used, but laminated is the safer choice over kitchens, stairs and seating areas.
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
What a typical job includes
- Made-to-measure aluminium roof lantern or framed skylight
- Survey of the roof, opening, upstand and drainage
- Fixing, glazing and sealing onto the prepared upstand
- Written guarantee terms and manufacturer documentation

Poole at a glance
- Postcodes covered
- BH15, BH14, BH17 and the surrounding area, including Bournemouth, Ferndown and Christchurch
- Coast
- Poole is about 1 km from the coast or a tidal estuary, so salt air and wind-driven rain are worth planning for. Coastal lanterns face salt deposits on the glass and frames and strong uplift from wind on exposed roofs. Marine-grade coatings, stainless fixings and secure fixing to a well-built upstand matter, and salt film may need rinsing more often than self-cleaning glass manages alone.
- Daylight and sun
- In Poole the midwinter sun reaches about 16° above the horizon at noon, with roughly 7.7 hours of daylight, rising to about 63° and 16.3 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Getting a large lantern onto a terraced flat roof may mean carrying it through the house or lifting it over neighbouring property, so access is planned at survey. Lanterns near a boundary raise fire performance questions, and conservation areas may restrict raised glazing.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Poole
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Approved Document F covers ventilation. Replacing windows should not leave a room with worse background ventilation than before, which is why replacement windows often include trickle vents.
Choosing your roof lanterns
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Square or octagonal lantern
A pyramid or eight-sided design that suits square rooms, orangeries and spaces where a central focal point is wanted.
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Roof Lanterns in Poole: questions
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Will a roof lantern make my room too hot?
A roof lantern can add heat on sunny days, especially facing south or west, because overhead glass receives sun for much of the day. Solar-control glass, opening vents and blinds help keep the room comfortable. The glass is chosen at survey based on the lantern's size and orientation and how the room is used.
How much does a roof lantern cost?
The cost of a roof lantern depends on its size and shape, the glass specification, frame colour, any opening vents, and whether the upstand exists or needs building. Access to the roof and lifting a large lantern also affect labour. See the guide prices for typical ranges; the written quote fixes the price for your exact specification.
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
Do you cover Poole for roof lanterns?
Yes. We can quote for roof lanterns across Poole and the surrounding Dorset area, including postcode districts BH15, BH14 and BH17, and nearby Bournemouth, Ferndown and Christchurch. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Poole
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.