Acton · Greater London
Roof Lanterns in Acton
If your skylight in Acton drips with condensation or leaks around the frame, we can survey it and quote for a modern, thermally broken replacement.
- W3
- W5
- W4
- Guide from £1,095
Aluminium roof lantern across Acton
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
Old polycarbonate or single glazed roof lanterns can be replaced with double glazed aluminium lanterns on the existing upstand, if the upstand is sound, level and the right size. Upstands that are rotten, uninsulated or out of level should be rebuilt first, which the survey identifies.
Roof lanterns are made in rectangular, square and octagonal shapes, with hipped or gable ends. Frames are usually powder-coated aluminium, often grey or black outside and white inside. Manufacturing lead times depend on size and colour, and the expected timescale is confirmed in writing with the quote.
What's included
- Fixing, glazing and sealing onto the prepared upstand
- Removal and disposal of an old lantern or skylight
- Written guarantee terms and manufacturer documentation
- Survey of the roof, opening, upstand and drainage

Acton at a glance
- Postcodes covered
- W3, W5, W4 and the surrounding area, including Chiswick, Ealing and Shepherds Bush
- Coast
- Acton is well inland, around 45 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Acton the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Getting a large lantern onto a terraced flat roof may mean carrying it through the house or lifting it over neighbouring property, so access is planned at survey. Lanterns near a boundary raise fire performance questions, and conservation areas may restrict raised glazing.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Acton
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Approved Document F covers ventilation. Replacing windows should not leave a room with worse background ventilation than before, which is why replacement windows often include trickle vents.
Specification choices
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Roof Lanterns in Acton: questions
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
What guarantee comes with a roof lantern?
Manufacturer guarantees apply to the frame, coating and sealed units, and the terms are confirmed in writing. The upstand and roof covering may be covered separately, depending on who builds them. Guarantee terms for the installation are set out in writing with your quote, so you know exactly what is covered before going ahead.
Do you cover Acton for roof lanterns?
Yes. We can quote for roof lanterns across Acton and the surrounding Greater London area, including postcode districts W3, W5 and W4, and nearby Chiswick, Ealing and Shepherds Bush. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Acton
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.