A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
In England, Approved Document L sets a limiting U-value of 2.2 W/m²K for rooflights, calculated in the horizontal position, for both new and existing homes. A kerb or upstand built on site should achieve 0.35 W/m²K or better. Ask for the lantern's declared horizontal U-value, not a vertical figure.
In England, a rooflight on a house is usually permitted development if it projects no more than 150mm beyond the roof plane and is no higher than the highest part of the roof. Raised lanterns often stand taller than that, so check with the council before ordering.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
What a typical job includes
- Fixing, glazing and sealing onto the prepared upstand
- Sealed double glazed units with laminated inner pane options
- Made-to-measure aluminium roof lantern or framed skylight
- Survey of the roof, opening, upstand and drainage

Working in Camden
- Postcodes covered
- NW1, N1C, NW5 and the surrounding area, including Islington, Cricklewood and Kensington
- Coast
- Camden is well inland, around 37 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Camden the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Getting a large lantern onto a terraced flat roof may mean carrying it through the house or lifting it over neighbouring property, so access is planned at survey. Lanterns near a boundary raise fire performance questions, and conservation areas may restrict raised glazing.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Camden
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
In England, replacing a whole window, roof window or glazed external door is building work. It has to be notified to building control, either by an installer registered with a competent person scheme such as FENSA or Certass, or through a building notice to the council. Replacing only the glass in an existing frame is a repair and is not notifiable.
What you can choose
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Roof Lanterns in Camden: questions
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
How much does a roof lantern cost?
The cost of a roof lantern depends on its size and shape, the glass specification, frame colour, any opening vents, and whether the upstand exists or needs building. Access to the roof and lifting a large lantern also affect labour. See the guide prices for typical ranges; the written quote fixes the price for your exact specification.
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
Do you cover Camden for roof lanterns?
Yes. We can quote for roof lanterns across Camden and the surrounding Greater London area, including postcode districts NW1, N1C and NW5, and nearby Islington, Cricklewood and Kensington. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Camden
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.