Peckham · Greater London
Roof Lanterns in Peckham
A roof lantern in Peckham can flood a dark extension or kitchen with daylight from above, and our glaziers check the roof and upstand before you receive a fixed written quote.
- SE15
- SE5
- SE14
- Guide from £1,095
Aluminium roof lantern across Peckham
In England, a rooflight on a house is usually permitted development if it projects no more than 150mm beyond the roof plane and is no higher than the highest part of the roof. Raised lanterns often stand taller than that, so check with the council before ordering.
In England, Approved Document L sets a limiting U-value of 2.2 W/m²K for rooflights, calculated in the horizontal position, for both new and existing homes. A kerb or upstand built on site should achieve 0.35 W/m²K or better. Ask for the lantern's declared horizontal U-value, not a vertical figure.
The Rooflight Association recommends laminated glass for the inner pane of glass rooflights, because laminated glass stays bonded together if it breaks instead of dropping fragments into the room below. Toughened inner panes are still used, but laminated is the safer choice over kitchens, stairs and seating areas.
The price of a roof lantern or skylight depends on the size and shape, glass specification, frame colour, opening vents or electric operation, and whether the upstand already exists or needs building. Access to the roof and lifting large units add labour. See the guide prices for typical ranges.
What you get
- Fixing, glazing and sealing onto the prepared upstand
- Sealed double glazed units with laminated inner pane options
- Survey of the roof, opening, upstand and drainage
- Written guarantee terms and manufacturer documentation

Peckham at a glance
- Postcodes covered
- SE15, SE5, SE14 and the surrounding area, including Brixton, Greenwich and Lewisham
- Coast
- Peckham is well inland, around 30 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Peckham the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Getting a large lantern onto a terraced flat roof may mean carrying it through the house or lifting it over neighbouring property, so access is planned at survey. Lanterns near a boundary raise fire performance questions, and conservation areas may restrict raised glazing.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Peckham
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Approved Document L sets the minimum energy performance for replacement windows and doors in existing homes in England: a U-value of 1.4 W/m²K, or Window Energy Rating band B for windows; doors can instead meet a Door Set Energy Rating (band B, or band C for doors more than 60% glazed); rooflights need 2.2 W/m²K.
Options to choose between
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Square or octagonal lantern
A pyramid or eight-sided design that suits square rooms, orangeries and spaces where a central focal point is wanted.
Roof Lanterns in Peckham: questions
Do I need planning permission for a roof lantern?
Sometimes. In England, rooflights on a house are usually permitted development if they project no more than 150mm above the roof plane and are no higher than the highest part of the roof. Raised lanterns often exceed that, and flats, listed buildings and conservation areas have extra controls, so check with your council first.
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
What guarantee comes with a roof lantern?
Manufacturer guarantees apply to the frame, coating and sealed units, and the terms are confirmed in writing. The upstand and roof covering may be covered separately, depending on who builds them. Guarantee terms for the installation are set out in writing with your quote, so you know exactly what is covered before going ahead.
Do you cover Peckham for roof lanterns?
Yes. We can quote for roof lanterns across Peckham and the surrounding Greater London area, including postcode districts SE15, SE5 and SE14, and nearby Brixton, Greenwich and Lewisham. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Peckham
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.