Deal · Kent
Roof Lanterns in Deal
Is the middle of your extension in Deal too dark? A roof lantern or skylight brings in light that wall windows cannot reach.
- CT14
- Guide from £1,095
Roof lantern replacement for homes and businesses in Deal
The Rooflight Association recommends laminated glass for the inner pane of glass rooflights, because laminated glass stays bonded together if it breaks instead of dropping fragments into the room below. Toughened inner panes are still used, but laminated is the safer choice over kitchens, stairs and seating areas.
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
What a typical job includes
- Survey of the roof, opening, upstand and drainage
- Written guarantee terms and manufacturer documentation
- Fixing, glazing and sealing onto the prepared upstand
- Sealed double glazed units with laminated inner pane options

Working in Deal
- Postcodes covered
- CT14 and the surrounding area, including Dover, Ramsgate and Broadstairs
- Coast
- Deal is about 1 km from the coast or a tidal estuary, so salt air and wind-driven rain are worth planning for. Coastal lanterns face salt deposits on the glass and frames and strong uplift from wind on exposed roofs. Marine-grade coatings, stainless fixings and secure fixing to a well-built upstand matter, and salt film may need rinsing more often than self-cleaning glass manages alone.
- Daylight and sun
- In Deal the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Deal
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
If the glass sits in a fire-resisting door or screen, such as a flat entrance door or a commercial corridor screen, it must be replaced with fire-rated glazing tested as part of that system. Ordinary toughened glass is not a substitute.
Specification choices
Square or octagonal lantern
A pyramid or eight-sided design that suits square rooms, orangeries and spaces where a central focal point is wanted.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Roof Lanterns in Deal: questions
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Do you cover Deal for roof lanterns?
Yes. We can quote for roof lanterns across Deal and the surrounding Kent area, including postcode districts CT14, and nearby Dover, Ramsgate and Broadstairs. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Deal
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.