Rawtenstall · Lancashire
Roof Lanterns in Rawtenstall
Is the middle of your extension in Rawtenstall too dark? A roof lantern or skylight brings in light that wall windows cannot reach.
- BB4
- OL13
- Guide from £1,095
Flat roof skylight for homes and businesses in Rawtenstall
In England, Approved Document L sets a limiting U-value of 2.2 W/m²K for rooflights, calculated in the horizontal position, for both new and existing homes. A kerb or upstand built on site should achieve 0.35 W/m²K or better. Ask for the lantern's declared horizontal U-value, not a vertical figure.
Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.
The Rooflight Association recommends laminated glass for the inner pane of glass rooflights, because laminated glass stays bonded together if it breaks instead of dropping fragments into the room below. Toughened inner panes are still used, but laminated is the safer choice over kitchens, stairs and seating areas.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
What a typical job includes
- Made-to-measure aluminium roof lantern or framed skylight
- Fixing, glazing and sealing onto the prepared upstand
- Survey of the roof, opening, upstand and drainage
- Written guarantee terms and manufacturer documentation

Working in Rawtenstall
- Postcodes covered
- BB4, OL13 and the surrounding area, including Accrington, Bury and Burnley
- Coast
- Rawtenstall is well inland, around 42 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Rawtenstall the midwinter sun reaches about 13° above the horizon at noon, with roughly 7.2 hours of daylight, rising to about 60° and 16.8 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Rawtenstall
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Replacing windows and doors with similar ones is usually permitted development for houses in England. Flats, listed buildings and homes in conservation areas or covered by an Article 4 direction can need permission, so check with the council first.
Choosing your roof lanterns
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Roof Lanterns in Rawtenstall: questions
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
Do you cover Rawtenstall for roof lanterns?
Yes. We can quote for roof lanterns across Rawtenstall and the surrounding Lancashire area, including postcode districts BB4 and OL13, and nearby Accrington, Bury and Burnley. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Rawtenstall
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.