Irvinestown · County Fermanagh
Roof Lanterns in Irvinestown
Old polycarbonate lanterns in Irvinestown that leak, rattle or have yellowed can usually be replaced with a double glazed aluminium lantern on a sound upstand.
- BT94
- Guide from £1,095
Flat roof skylight in Irvinestown
Cutting a new opening for a roof lantern or skylight usually means trimming joists or rafters, so the roof can carry the load around the hole. Building regulations approval is generally needed for a new rooflight, covering structure, energy performance and, near a boundary, fire performance.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.
Glass for lanterns usually comes with a self-cleaning outer coating that helps rain wash away dirt, and a choice of clear, neutral or blue-tinted solar-control glass. Solar-control glass limits heat build-up under a south-facing lantern, while clear low-E glass suits shaded or north-facing rooms.
What's included
- Removal and disposal of an old lantern or skylight
- Fixing, glazing and sealing onto the prepared upstand
- Sealed double glazed units with laminated inner pane options
- Survey of the roof, opening, upstand and drainage

Local details for Irvinestown
- Postcodes covered
- BT94 and the surrounding area, including Enniskillen, Omagh and Lisnaskea
- Coast
- Irvinestown is well inland, around 37 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Irvinestown the midwinter sun reaches about 12° above the horizon at noon, with roughly 7.0 hours of daylight, rising to about 59° and 17.0 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in Northern Ireland
- Technical Booklet V covers safety glazing in Northern Ireland, including glass in and around doors and low-level glazing where people could walk into it.
Guide prices in Irvinestown
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Glass in a fire-resisting door or screen must be replaced with fire-rated glazing tested as part of that system. Ordinary toughened glass is not a substitute.
Choosing your roof lanterns
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Roof Lanterns in Irvinestown: questions
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
Do you cover Irvinestown for roof lanterns?
Yes. We can quote for roof lanterns across Irvinestown and the surrounding County Fermanagh area, including postcode districts BT94, and nearby Enniskillen, Omagh and Lisnaskea. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Irvinestown
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.