Call 0800 088 6248

Pembroke Dock · Dyfed

Roof Lanterns in Pembroke Dock

Our glaziers fit roof lanterns across Pembroke Dock, glazing and sealing each unit onto its upstand and explaining any building regulations approval the work needs.

  • SA72
  • Guide from £1,095

Get your free quote

Start with your postcode. A glazier will be in touch to arrange a free survey.

By sending this form you agree we can contact you about this enquiry. See our privacy policy for how we use your details.

No obligation. Prefer to talk? Call 0800 088 6248 or WhatsApp us.

Aluminium roof lantern in Pembroke Dock

Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.

Old polycarbonate or single glazed roof lanterns can be replaced with double glazed aluminium lanterns on the existing upstand, if the upstand is sound, level and the right size. Upstands that are rotten, uninsulated or out of level should be rebuilt first, which the survey identifies.

Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.

Roof lanterns are made in rectangular, square and octagonal shapes, with hipped or gable ends. Frames are usually powder-coated aluminium, often grey or black outside and white inside. Manufacturing lead times depend on size and colour, and the expected timescale is confirmed in writing with the quote.

What a typical job includes

  • Sealed double glazed units with laminated inner pane options
  • Survey of the roof, opening, upstand and drainage
  • Made-to-measure aluminium roof lantern or framed skylight
  • Fixing, glazing and sealing onto the prepared upstand
Roof lantern above a kitchen island in an open-plan extension

Working in Pembroke Dock

Postcodes covered
SA72 and the surrounding area, including Milford Haven, Haverfordwest and Tenby
Coast
Pembroke Dock is about 2 km from the coast or a tidal estuary, so salt air and wind-driven rain are worth planning for. Coastal lanterns face salt deposits on the glass and frames and strong uplift from wind on exposed roofs. Marine-grade coatings, stainless fixings and secure fixing to a well-built upstand matter, and salt film may need rinsing more often than self-cleaning glass manages alone.
Daylight and sun
In Pembroke Dock the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
Access and setting
Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
Rules in Wales
In Wales, Approved Document N covers safety glazing: safety glass is needed in and around doors and in low-level glazing where people could walk into it.

Guide prices in Pembroke Dock

Guide prices inc VAT for typical jobs. Remote and island locations are quoted by arrangement. Your written quote fixes the price after measuring.
Typical jobGuide price inc VAT
Lantern 1500 × 1000 mm, fitted to a kerb£1,395 – £1,795
Lantern 2000 × 1000 mm£1,695 – £2,095
Lantern 3000 × 1500 mm£2,795 – £3,695
Flat glass rooflight 1000 × 1000 mm£1,095 – £1,395

Get a guide price for your size

Like-for-like replacement windows on houses in Wales are usually permitted development, but flats, listed buildings and conservation areas can need permission. Check with the local planning authority.

Specification choices

Flat framed skylight

A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.

Opening vents

Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.

Solar-control glass

Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.

Roof Lanterns in Pembroke Dock: questions

Can I replace my old polycarbonate roof lantern with glass?

Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.

How long does it take to fit a roof lantern?

Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.

What guarantee comes with a roof lantern?

Manufacturer guarantees apply to the frame, coating and sealed units, and the terms are confirmed in writing. The upstand and roof covering may be covered separately, depending on who builds them. Guarantee terms for the installation are set out in writing with your quote, so you know exactly what is covered before going ahead.

How much does a roof lantern cost?

The cost of a roof lantern depends on its size and shape, the glass specification, frame colour, any opening vents, and whether the upstand exists or needs building. Access to the roof and lifting a large lantern also affect labour. See the guide prices for typical ranges; the written quote fixes the price for your exact specification.

Do you cover Pembroke Dock for roof lanterns?

Yes. We can quote for roof lanterns across Pembroke Dock and the surrounding Dyfed area, including postcode districts SA72, and nearby Milford Haven, Haverfordwest and Tenby. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.

Get a written quote in Pembroke Dock

Free survey for new glazing, clear guide prices and one point of contact for every glazing job.

CallGet a quote