Old polycarbonate lanterns in Hitchin that leak, rattle or have yellowed can usually be replaced with a double glazed aluminium lantern on a sound upstand.
- SG6
- Guide from £1,095
Hitchin: roof lanterns
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
Glass for lanterns usually comes with a self-cleaning outer coating that helps rain wash away dirt, and a choice of clear, neutral or blue-tinted solar-control glass. Solar-control glass limits heat build-up under a south-facing lantern, while clear low-E glass suits shaded or north-facing rooms.
Warm, moist air rises and collects in a roof lantern, so condensation can form on cold winter mornings, especially over kitchens and bathrooms. Thermally broken frames, warm-edge spacers and good room ventilation reduce it, and opening vents in the lantern can release warm air in summer.
In England, a rooflight on a house is usually permitted development if it projects no more than 150mm beyond the roof plane and is no higher than the highest part of the roof. Raised lanterns often stand taller than that, so check with the council before ordering.
What a typical job includes
- Written guarantee terms and manufacturer documentation
- Survey of the roof, opening, upstand and drainage
- Fixing, glazing and sealing onto the prepared upstand
- Made-to-measure aluminium roof lantern or framed skylight

Hitchin at a glance
- Postcodes covered
- SG6 and the surrounding area, including Letchworth Garden City, Stevenage and Luton
- Coast
- Hitchin is well inland, around 70 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Hitchin the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.5 hours of daylight, rising to about 62° and 16.5 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Hitchin
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Listed buildings in England need listed building consent for most changes to historic windows or glass, and conservation areas can restrict changes visible from the street. Speak to the council's conservation officer before ordering.
Options to choose between
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Roof Lanterns in Hitchin: questions
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
What guarantee comes with a roof lantern?
Manufacturer guarantees apply to the frame, coating and sealed units, and the terms are confirmed in writing. The upstand and roof covering may be covered separately, depending on who builds them. Guarantee terms for the installation are set out in writing with your quote, so you know exactly what is covered before going ahead.
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
How much does a roof lantern cost?
The cost of a roof lantern depends on its size and shape, the glass specification, frame colour, any opening vents, and whether the upstand exists or needs building. Access to the roof and lifting a large lantern also affect labour. See the guide prices for typical ranges; the written quote fixes the price for your exact specification.
Do you cover Hitchin for roof lanterns?
Yes. We can quote for roof lanterns across Hitchin and the surrounding Hertfordshire area, including postcode districts SG6, and nearby Letchworth Garden City, Stevenage and Luton. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Hitchin
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.