Redhill · Surrey
Roof Lanterns in Redhill
Our glaziers fit roof lanterns across Redhill, glazing and sealing each unit onto its upstand and explaining any building regulations approval the work needs.
- RH1
- RH2
- Guide from £1,095
Redhill: opening skylights
Glass for lanterns usually comes with a self-cleaning outer coating that helps rain wash away dirt, and a choice of clear, neutral or blue-tinted solar-control glass. Solar-control glass limits heat build-up under a south-facing lantern, while clear low-E glass suits shaded or north-facing rooms.
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
What a typical job includes
- Survey of the roof, opening, upstand and drainage
- Removal and disposal of an old lantern or skylight
- Made-to-measure aluminium roof lantern or framed skylight
- Sealed double glazed units with laminated inner pane options

About Redhill for this job
- Postcodes covered
- RH1, RH2 and the surrounding area, including Reigate, Horley and Caterham
- Coast
- Redhill is well inland, around 44 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Redhill the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Redhill
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
In England, replacing a whole window, roof window or glazed external door is building work. It has to be notified to building control, either by an installer registered with a competent person scheme such as FENSA or Certass, or through a building notice to the council. Replacing only the glass in an existing frame is a repair and is not notifiable.
Options to choose between
Frame colours
Powder-coated aluminium in grey, black, white or other RAL colours, often dual colour to suit the roof and the room.
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Roof Lanterns in Redhill: questions
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Do I need planning permission for a roof lantern?
Sometimes. In England, rooflights on a house are usually permitted development if they project no more than 150mm above the roof plane and are no higher than the highest part of the roof. Raised lanterns often exceed that, and flats, listed buildings and conservation areas have extra controls, so check with your council first.
How do I clean a roof lantern?
Self-cleaning coated glass lets rain lift most dirt, but a rinse with clean water in long dry spells helps. Clean from a safe position at the roof edge or from a suitable platform, never by standing on the lantern. Wipe the inside glass with mild soapy water, and keep leaves clear of the upstand and roof outlets.
How much does a roof lantern cost?
The cost of a roof lantern depends on its size and shape, the glass specification, frame colour, any opening vents, and whether the upstand exists or needs building. Access to the roof and lifting a large lantern also affect labour. See the guide prices for typical ranges; the written quote fixes the price for your exact specification.
Do you cover Redhill for roof lanterns?
Yes. We can quote for roof lanterns across Redhill and the surrounding Surrey area, including postcode districts RH1 and RH2, and nearby Reigate, Horley and Caterham. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Redhill
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.