Reigate · Surrey
Roof Lanterns in Reigate
Old polycarbonate lanterns in Reigate that leak, rattle or have yellowed can usually be replaced with a double glazed aluminium lantern on a sound upstand.
- RH2
- RH1
- RH3
- Guide from £1,095
Roof lantern replacement in Reigate: what to know
Cutting a new opening for a roof lantern or skylight usually means trimming joists or rafters, so the roof can carry the load around the hole. Building regulations approval is generally needed for a new rooflight, covering structure, energy performance and, near a boundary, fire performance.
Roof lanterns are made in rectangular, square and octagonal shapes, with hipped or gable ends. Frames are usually powder-coated aluminium, often grey or black outside and white inside. Manufacturing lead times depend on size and colour, and the expected timescale is confirmed in writing with the quote.
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
In England, a rooflight on a house is usually permitted development if it projects no more than 150mm beyond the roof plane and is no higher than the highest part of the roof. Raised lanterns often stand taller than that, so check with the council before ordering.
What you get
- Sealed double glazed units with laminated inner pane options
- Removal and disposal of an old lantern or skylight
- Survey of the roof, opening, upstand and drainage
- Fixing, glazing and sealing onto the prepared upstand

Local details for Reigate
- Postcodes covered
- RH2, RH1, RH3 and the surrounding area, including Redhill, Horley and Banstead
- Coast
- Reigate is well inland, around 45 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Reigate the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Reigate
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
Listed buildings in England need listed building consent for most changes to historic windows or glass, and conservation areas can restrict changes visible from the street. Speak to the council's conservation officer before ordering.
Specification choices
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Roof Lanterns in Reigate: questions
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Do you cover Reigate for roof lanterns?
Yes. We can quote for roof lanterns across Reigate and the surrounding Surrey area, including postcode districts RH2, RH1 and RH3, and nearby Redhill, Horley and Banstead. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Reigate
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.