Putney · Greater London
Roof Lanterns in Putney
A roof lantern in Putney can flood a dark extension or kitchen with daylight from above, and our glaziers check the roof and upstand before you receive a fixed written quote.
- SW15
- SW6
- SW18
- Guide from £1,095
About opening skylights in Putney
Roof lanterns are made in rectangular, square and octagonal shapes, with hipped or gable ends. Frames are usually powder-coated aluminium, often grey or black outside and white inside. Manufacturing lead times depend on size and colour, and the expected timescale is confirmed in writing with the quote.
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
In England, Approved Document L sets a limiting U-value of 2.2 W/m²K for rooflights, calculated in the horizontal position, for both new and existing homes. A kerb or upstand built on site should achieve 0.35 W/m²K or better. Ask for the lantern's declared horizontal U-value, not a vertical figure.
Opening skylights and lantern vents can be manual or electrically operated, often with a rain sensor that closes them automatically when it starts to rain. Electric vents need a power supply planned before plastering, so the wiring route is agreed at survey when an opening option is chosen.
What you get
- Made-to-measure aluminium roof lantern or framed skylight
- Survey of the roof, opening, upstand and drainage
- Sealed double glazed units with laminated inner pane options
- Written guarantee terms and manufacturer documentation

Local details for Putney
- Postcodes covered
- SW15, SW6, SW18 and the surrounding area, including Wandsworth, Barnes and Fulham
- Coast
- Putney is well inland, around 40 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Putney the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.6 hours of daylight, rising to about 62° and 16.4 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Getting a large lantern onto a terraced flat roof may mean carrying it through the house or lifting it over neighbouring property, so access is planned at survey. Lanterns near a boundary raise fire performance questions, and conservation areas may restrict raised glazing.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Putney
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
If the glass sits in a fire-resisting door or screen, such as a flat entrance door or a commercial corridor screen, it must be replaced with fire-rated glazing tested as part of that system. Ordinary toughened glass is not a substitute.
Specification choices
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Square or octagonal lantern
A pyramid or eight-sided design that suits square rooms, orangeries and spaces where a central focal point is wanted.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Roof Lanterns in Putney: questions
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
Do I need planning permission for a roof lantern?
Sometimes. In England, rooflights on a house are usually permitted development if they project no more than 150mm above the roof plane and are no higher than the highest part of the roof. Raised lanterns often exceed that, and flats, listed buildings and conservation areas have extra controls, so check with your council first.
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Do you cover Putney for roof lanterns?
Yes. We can quote for roof lanterns across Putney and the surrounding Greater London area, including postcode districts SW15, SW6 and SW18, and nearby Wandsworth, Barnes and Fulham. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Putney
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.