Hertford · Hertfordshire
Roof Lanterns in Hertford
A roof lantern in Hertford can flood a dark extension or kitchen with daylight from above, and our glaziers check the roof and upstand before you receive a fixed written quote.
- SG13
- SG14
- Guide from £1,095
Opening skylights in Hertford
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
In England, a rooflight on a house is usually permitted development if it projects no more than 150mm beyond the roof plane and is no higher than the highest part of the roof. Raised lanterns often stand taller than that, so check with the council before ordering.
The Rooflight Association recommends laminated glass for the inner pane of glass rooflights, because laminated glass stays bonded together if it breaks instead of dropping fragments into the room below. Toughened inner panes are still used, but laminated is the safer choice over kitchens, stairs and seating areas.
Glass for lanterns usually comes with a self-cleaning outer coating that helps rain wash away dirt, and a choice of clear, neutral or blue-tinted solar-control glass. Solar-control glass limits heat build-up under a south-facing lantern, while clear low-E glass suits shaded or north-facing rooms.
Included as standard
- Removal and disposal of an old lantern or skylight
- Written guarantee terms and manufacturer documentation
- Survey of the roof, opening, upstand and drainage
- Made-to-measure aluminium roof lantern or framed skylight

Working in Hertford
- Postcodes covered
- SG13, SG14 and the surrounding area, including Hoddesdon, Welwyn Garden City and Hatfield
- Coast
- Hertford is well inland, around 49 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Hertford the midwinter sun reaches about 15° above the horizon at noon, with roughly 7.5 hours of daylight, rising to about 62° and 16.5 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Hertford
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
If the glass sits in a fire-resisting door or screen, such as a flat entrance door or a commercial corridor screen, it must be replaced with fire-rated glazing tested as part of that system. Ordinary toughened glass is not a substitute.
Options to choose between
Rectangular hipped lantern
A long ridge with hipped ends, suiting most rectangular extensions and kitchens, sized to the opening and the room below.
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Flat framed skylight
A low-profile framed rooflight on a flat roof upstand, fixed or opening, for bathrooms, landings and smaller rooms.
Roof Lanterns in Hertford: questions
Will a roof lantern make my room too hot?
A roof lantern can add heat on sunny days, especially facing south or west, because overhead glass receives sun for much of the day. Solar-control glass, opening vents and blinds help keep the room comfortable. The glass is chosen at survey based on the lantern's size and orientation and how the room is used.
Can I replace my old polycarbonate roof lantern with glass?
Yes, in most cases. A glass lantern is heavier than polycarbonate, so the upstand and roof structure must be able to carry it. If the upstand is sound, level and the right size, a new aluminium lantern can usually sit on it. If not, the upstand is rebuilt first, which the survey will identify.
How long does it take to fit a roof lantern?
Fitting a roof lantern on a prepared upstand usually takes a day or less for a typical size, longer for large or complex shapes. The lantern is made to order first, and the lead time depends on its size, shape and colour. Building or rebuilding an upstand is separate roofing work that comes before fitting.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Do you cover Hertford for roof lanterns?
Yes. We can quote for roof lanterns across Hertford and the surrounding Hertfordshire area, including postcode districts SG13 and SG14, and nearby Hoddesdon, Welwyn Garden City and Hatfield. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Hertford
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.