Horsham · West Sussex
Roof Lanterns in Horsham
Homeowners in Horsham can get a written roof lantern quote that fixes the price for the size, shape, glass, colour and vents shown.
- RH12
- Guide from £1,095
About opening skylights in Horsham
A roof lantern is assembled from an aluminium ridge, hip bars and glazing bars that hold sealed glass units on each pitch. It sits on an upstand built around the roof opening. The upstand should be level, weathered into the roof covering and insulated, because a poor upstand causes most leaks and cold spots.
Old polycarbonate or single glazed roof lanterns can be replaced with double glazed aluminium lanterns on the existing upstand, if the upstand is sound, level and the right size. Upstands that are rotten, uninsulated or out of level should be rebuilt first, which the survey identifies.
Roof lanterns are not designed to be walked on, so never stand or lean on the glass or bars. Cleaning and inspection should be done from safe access at the edge of the roof. Keep leaves and debris away from the upstand and roof outlets so water drains freely.
The price of a roof lantern or skylight depends on the size and shape, glass specification, frame colour, opening vents or electric operation, and whether the upstand already exists or needs building. Access to the roof and lifting large units add labour. See the guide prices for typical ranges.
Included as standard
- Removal and disposal of an old lantern or skylight
- Survey of the roof, opening, upstand and drainage
- Made-to-measure aluminium roof lantern or framed skylight
- Fixing, glazing and sealing onto the prepared upstand

Working in Horsham
- Postcodes covered
- RH12 and the surrounding area, including Crawley, Horley and Haywards Heath
- Coast
- Horsham is well inland, around 26 km from the nearest coast, so salt exposure is not usually a factor.
- Daylight and sun
- In Horsham the midwinter sun reaches about 16° above the horizon at noon, with roughly 7.7 hours of daylight, rising to about 62° and 16.3 hours in midsummer. Overhead glazing receives far more light than a wall window of the same size, especially when the sun is high in summer. South-facing lanterns may need solar-control glass, while low winter sun and north-facing rooms benefit from clear, high light-transmission low-E glass.
- Access and setting
- Rural roofs collect more leaves, moss and bird debris, so lanterns need clear upstand drainage and regular checks. Exposed sites see higher wind loads and driving rain, and older outbuildings may need the roof structure strengthening before a lantern is added.
- Rules in England
- Approved Document K requires safety glass in critical locations in England: glazing in doors and in side panels within 300 mm of a door, up to 1500 mm above floor level, and any glazing in walls or partitions up to 800 mm above floor level.
Guide prices in Horsham
| Typical job | Guide price inc VAT |
|---|---|
| Lantern 1500 × 1000 mm, fitted to a kerb | £1,395 – £1,795 |
| Lantern 2000 × 1000 mm | £1,695 – £2,095 |
| Lantern 3000 × 1500 mm | £2,795 – £3,695 |
| Flat glass rooflight 1000 × 1000 mm | £1,095 – £1,395 |
Get a guide price for your size
If the glass sits in a fire-resisting door or screen, such as a flat entrance door or a commercial corridor screen, it must be replaced with fire-rated glazing tested as part of that system. Ordinary toughened glass is not a substitute.
Options to choose between
Solar-control glass
Neutral or blue-tinted coatings that reduce heat build-up under south or west-facing lanterns while keeping daylight levels high.
Opening vents
Manual or electric vents in the lantern or skylight, with optional rain sensors that close them automatically in wet weather.
Square or octagonal lantern
A pyramid or eight-sided design that suits square rooms, orangeries and spaces where a central focal point is wanted.
Roof Lanterns in Horsham: questions
Does fitting a roof lantern need building regulations approval?
A new roof lantern or skylight generally needs building regulations approval, because the roof structure is cut and must be supported, and the unit must meet energy standards. Fire performance also matters near a boundary. Replacing a lantern on an existing sound upstand is simpler, and we explain which route applies at survey.
Should the inner glass in a roof lantern be laminated?
Laminated inner glass is the safer choice and is recommended by the Rooflight Association. If a laminated pane breaks, the interlayer holds the pieces together, so glass is far less likely to fall into the room below. This matters most over kitchens, dining tables, stairs and seating, and it is offered as a standard option.
Why does my roof lantern get condensation?
Condensation forms when warm, moist air from cooking, bathing or drying clothes meets the colder glass and frames at high level. Older single glazed or non thermally broken lanterns suffer most. Thermally broken frames, warm-edge spacers, extractor fans and opening vents reduce it. Some condensation on very cold mornings is normal and clears as the room warms.
Will a roof lantern make my room too hot?
A roof lantern can add heat on sunny days, especially facing south or west, because overhead glass receives sun for much of the day. Solar-control glass, opening vents and blinds help keep the room comfortable. The glass is chosen at survey based on the lantern's size and orientation and how the room is used.
Do you cover Horsham for roof lanterns?
Yes. We can quote for roof lanterns across Horsham and the surrounding West Sussex area, including postcode districts RH12, and nearby Crawley, Horley and Haywards Heath. Start with your postcode on the quote form and a glazier will arrange a free survey before giving you a written quote.
Get a written quote in Horsham
Free survey for new glazing, clear guide prices and one point of contact for every glazing job.